Phone #: 800-280-8987
APC AP9320 Environmental Management System
Brand: APC
Part Number: AP9320

$1,068.99

Product Details:

Description:

The APC Environmental Management System is a browser-accessible 1U rackmountable appliance that allows monitoring of a broad range of environmental and related conditions. While monitoring of one temperature, one humidity and one vibration sensor ship as standard, this flexible system allows you to add sensors to suit your needs. Early warnings of conditions that lead to equipment failure allow you to react to changes and minimize the impact on network availability. When conditions change, notifications are sent via email to the appropriate personnel. Eight input contacts provide for monitoring of other equipment. 2 output relays and controllable power outlets allow you to define actions remotely should conditions warrant it.

Features:

  • Access monitoring
  • Alarm Beacon
  • Browser accessible
  • Building Management System Integration
  • Customizable input contacts
  • Customizable output relays
  • Data logging
  • Door sensors
  • Enterprise management system compatible
  • Event logging
  • Fault notification
  • Flash upgradeable firmware
  • Humidity monitoring
  • Leak detection
  • Local LED status
  • Optional sensors
  • Password Security
  • Rack mountable
  • Read-only access
  • Reboot equipment remotely
  • Remote device management
  • Telnet management
  • Temperature monitoring
  • Vibration monitoringSpecifications:
  • Device Type: Environment Monitoring Device
  • Height: 1U (Rack Units)
  • Interfaces: 1 x management - RS-232 - 9 pin D-Sub (DB-9) 8 x network - Ethernet 10Base-T/100Base-TX - RJ-45 2 x peripheral - A-Link
  • Net Weight: 6.00 lbs. ( 2.73 kg)
  • Maximum Height: 1.74 inches ( 44 mm)
  • Maximum Width: 17.10 inches (434 mm)
  • Maximum depth: 7.00 inches (178 mm)
  • Shipping Weight: 12.85 lbs. ( 5.84 kg)
  • Shipping Height: 8.30 inches (211 mm)
  • Shipping Width: 22.90 inches (582 mm)
  • Shipping Depth: 13.40 inches (340 mm)
  • Built-in Devices: Status LCD
  • Units per Pallet: 100.00
  • Operating Environment: 32 - 113 F (0 - 45 C)
  • Storage Temperature: 5 - 149 F (-15 - 65 C)
  • Network / Transport Protocol: TCP/IP
  • Remote Management Protocol: SNMP, Telnet, HTTP
  • Connectivity Technology: Wired
  • Data Link Protocol: Ethernet, Fast Ethernet
  • Communication Mode:Half-duplex, full-duplexables
  • Operating Relative Humidity: 0 - 95%
  • Storage Relative Humidity: 0 - 95%
  • Operating Elevation: 0-10000 feet (0-3000 meters)
  • Storage Elevation: 0-50000 feet (0-15000 meters)